Several variants of the DFT+U method exist.[1]{{cite|Himmetoglu:ijqc:2014}
Three types of DFT+U approaches are available in VASP. These are the following:
- LDAUTYPE=1: The rotationally invariant DFT+U introduced by Liechtenstein et al.[2]
- This particular flavour of DFT+U is of the form

- and is determined by the PAW on-site occupancies

- and the (unscreened) on-site electron-electron interaction

- where
are real spherical harmonics of angular momentum
=LDAUL.
- The unscreened electron-electron interaction
can be written in terms of the Slater integrals
,
,
, and
(
electrons). Using values for the Slater integrals calculated from atomic orbitals, however, would lead to a large overestimation of the true electron-electron interaction, since in solids the Coulomb interaction is screened (especially
).
- In practice these integrals are often treated as parameters, i.e., adjusted to reach agreement with experiment for a property like for instance the equilibrium volume, the magnetic moment or the band gap. They are normally specified in terms of the effective on-site Coulomb- and exchange parameters,
and
(LDAUU and LDAUJ, respectively).
and
can also be extracted from constrained-DFT calculations.
- These translate into values for the Slater integrals in the following way (as implemented in VASP at the moment):
 |
 |
 |
 |
|
 |
 |
 |
- |
-
|
 |
 |
 |
 |
-
|
 |
 |
 |
 |
|
- The essence of the DFT+U method consists of the assumption that one may now write the total energy as:

- where the Hartree-Fock like interaction replaces the semilocal on site due to the fact that one subtracts a double counting energy
, which supposedly equals the on-site semilocal contribution to the total energy,

- LDAUTYPE=2: The simplified (rotationally invariant) approach to the DFT+U, introduced by Dudarev et al.[3]
- This flavour of DFT+U is of the following form:
![{\displaystyle
E_{\mathrm{DFT+U}}=E_{\mathrm{LSDA}}+\frac{(U-J)}{2}\sum_\sigma \left[
\left(\sum_{m_1} n_{m_1,m_1}^{\sigma}\right) - \left(\sum_{m_1,m_2}
\hat n_{m_1,m_2}^{\sigma} \hat n_{m_2,m_1}^{\sigma} \right) \right].
}](/wiki/index.php?title=Special:MathShowImage&hash=c14b20c2a538ca3dd2c35d100d9bdade&mode=mathml)
- This can be understood as adding a penalty functional to the semilocal total energy expression that forces the on-site occupancy matrix in the direction of idempotency,
.
- Real matrices are only idempotent when their eigenvalues are either 1 or 0, which for an occupancy matrix translates to either fully occupied or fully unoccupied levels.
- Note: in Dudarev's approach the parameters
and
do not enter seperately, only the difference
is meaningful.
- LDAUTYPE=4: same as LDAUTYPE=1, but without exchange splitting (i.e., the total spin-up plus spin-down occupancy matrix is used). The double-counting term is given by

Warning: it is important to be aware of the fact that when using the DFT+U, in general the total energy will depend on the parameters
and
(LDAUU and LDAUJ, respectively). It is therefore not meaningful to compare the total energies resulting from calculations with different
and/or
, or
and in case of Dudarev's approach (LDAUTYPE=2).
Note on bandstructure calculation: the CHGCAR file contains only information up to angular momentum quantum number
=LMAXMIX for the on-site PAW occupancy matrices. When the CHGCAR file is read and kept fixed in the course of the calculations (ICHARG=11), the results will be necessarily not identical to a self-consistent run. The deviations are often large for DFT+U calculations. For the calculation of band structures within the DFT+U approach, it is hence strictly required to increase LMAXMIX to 4 (
elements) and 6 (
elements).
Related tags and articles
LDAU,
LDAUL,
LDAUU,
LDAUJ,
LDAUPRINT,
LMAXMIX
Examples that use this tag
References
- ↑ E. R. Ylvisaker and W. E. Pickett, Phys. Rev. B 79, 035103 (2009).
- ↑ A. I. Liechtenstein, V. I. Anisimov, and J. Zaanen, Phys. Rev. B 52, R5467 (1995).
- ↑ S. L. Dudarev, G. A. Botton, S. Y. Savrasov, C. J. Humphreys, and A. P. Sutton, Phys. Rev. B 57, 1505 (1998).